P0140 - O2 Sensor Circuit No Activity Detected (Bank 1 Sensor 2)
An oxygen sensor circuit issue was detected.
Code first. Confirm symptoms and checks before pricing parts.
Read code pattern
Check likely system
Estimate after confirmation
Explore Related Systems
Compare nearby repair families.
Code Overview
An oxygen sensor circuit issue was detected.
Common Causes
- Failed downstream oxygen sensor on bank 1 sensor 2
- Damaged wiring or poor terminal contact in the sensor circuit
- Exhaust leak affecting the downstream reading
- Sensor stuck inactive because of a separate fueling or catalyst problem
Symptoms
- Check-engine light with little or no drivability change
- Failed emissions readiness or inspection
- Downstream O2 data may stay flat on the scan tool
Diagnostic Steps
- Check for exhaust leaks and catalyst-related codes first
- Inspect the bank 1 sensor 2 wiring and connector near the exhaust
- Watch downstream sensor activity on the scan tool after warm-up
- Verify power, ground, and signal integrity before replacing the sensor
Repair Difficulty
Moderate
General difficulty estimate for the most common repair path.
Related OBD Codes
Browse nearby codes when systems overlap.
Next Steps
Move from code to checks, then estimate.